📋Basic Specifications

Model NO.XB3.0/XB3.5/XB4.0/MPA/MPD
SterilizationEthylene Oxide (EO)
Guarantee Period2 Years
GroupAdult
ApplicationInterventional Cardiology
ClassificationClass III
CertificateCE, ISO13485, FSC, CFDA
Specification6F / 8F
OriginChina
HS Code9018390000

🔍Product Description

Guiding Catheter Banner

Guiding Catheters are intended for use for intravascular introduction of interventional/diagnostic devices into coronary or peripheral vascular systems.

Product Diagram

Size Comparison Table

Terminal Configuration Models Outer Diameter (Fr/mm) Internal Diameter (mm) Length (cm)
Multifunctional (XB) XB3.0-6-100 6/2.06 1.80 100
XB3.5-6-100 6/2.06 1.80 100
XB4.0-6-100 6/2.06 1.80 100
XB4.5-6-100 6/2.06 1.80 100
Multipurpose (MP) MPA1-8-90 8/2.67 2.16 90
MPD-6-100 6/2.06 1.80 100
Separator

Key Features

  • Flat-wire-braided, 100-cm catheter shaft with PTFE liner
  • One-piece molded hub and strain relief
  • Curves specifically designed for transradial access
  • Radiopaque for precise fluoroscopic visualization
  • Soft, radiused tip for patient safety
  • Ultra-thin tube providing large lumen for smooth device delivery
  • Hydrophilic coating for reduced friction
  • Excellent kink resistance during procedures

⚙️Recommended Procedure

  1. Remove the guiding catheter from packaging using sterile techniques.
  2. Flush the catheter lumen with a heparinized saline solution.
  3. Ensure appropriate anticoagulation and vasodilation therapy is used.
  4. Introduce into vasculature via sheath or over an indwelling guidewire.
  5. Advance under fluoroscopic guidance to the desired position.
  6. Remove the guidewire before introducing other devices or contrast agents.

⚠️Complications

Use should be restricted to trained specialists. Potential complications include: hemorrhage, hematoma, allergic reaction, infection, embolism, blood vessel dissection, or occlusion.

Catheter Detail 1
Catheter Detail 2
Footer Banner
Technical Illustration

Frequently Asked Questions

Q1: How is the guiding catheter sterilized? The catheters are sterilized using Ethylene Oxide (EO) to ensure complete safety and sterility for surgical use.
Q2: What is the shelf life of the product? The product comes with a quality guarantee period of 2 years from the date of manufacture.
Q3: What are the primary materials used in construction? It features a flat-wire-braided shaft with a high-performance PTFE liner for smooth delivery and kink resistance.
Q4: Does the catheter support fluoroscopic visualization? Yes, the catheter is radiopaque, allowing for clear visualization under fluoroscopy during interventional procedures.
Q5: Which international certifications does this product hold? The catheter is fully certified with CE, ISO13485, FSC, and CFDA, meeting Class III medical instrument standards.
Q6: Are there different sizes available for various access points? Yes, we offer multiple sizes (6F and 8F) and specific curves like XB and MP designed for both transradial and femoral access.