Device Type
Human Blood Processor
Attribute
Department of Nephrology
Place of Use
Hospitals, Clinics and Emergency Centers
Transport Package
Wooden Carton
Specification
142cm x 49cm x 51cm
Origin
China
HS Code
9018904000
Production Capacity
1000 units/Month

Haemodialysis Machine W-T2008-B (HD)

Certification: With CE Certificate, IEC60601

15-inch LCD touch screen
Double needle dialysis treatment
Balance chamber + UF pump
UF control system with sealed double volume balancing chamber
8 kinds of UF profiling for clinical requirements
With Na, Bicarbonate and UF profiling
Standby battery (supplies power for 30 minutes)
Isolated UF function
Suitable for low flux and high flux dialyzer
Automatic self-checking function

Technical Data

ModelW-T2008-B
Dimensions (H*W*L)142cm x 49cm x 51cm
Floor Area65*45cm²
WeightApprox. 80KG
Input Power1500W
Circuit Voltage100-240Vac
Water Inlet Pressure0.1Mpa~0.6Mpa (15P.S.I~60P.S.I)
Water Inlet Temp5ºC~30ºC
Working Env10ºC~30ºC (Rel. humidity <=70%)

Disinfection & Sanitize Protocols

1. Hot Disinfection
30 mins; ~80ºC; Flow rate 500ml/min
2. Chemical Disinfection
30 mins; 36ºC~50ºC; Flow rate 500ml/min
3. Chemical with Heat
45 mins; 36ºC~80ºC; Flow rate 50ml/min
4. Rinse
10 mins; ~37ºC; Flow rate 800ml/min

Detailed Parameters

Dialysis Fluid FlowSelectable 300-800 mL/min
Temperature RangeSelectable 34.0ºC to 40.0ºC
Conductivity Range12 to 16 mS/cm (Accuracy ±0.1 mS/cm)
Acid ConcentrationDefault 1+34; Range 125 to 150 mmol/L
Heparin Pump0ml/h to 10ml/h; Syringe: 10, 20, 30, 50ml
Ultrafiltration Rate0ml/h~4000ml/h (Accuracy ±1%)
Blood Leak DetectorSensitivity ≤0.35 mL blood/min (HCT=32)
Optional Functions:
  • On-line BPM & Kt/V
  • Bi-cart Holder
  • Bacterial Filter Device
  • Patient Management Software System

Frequently Asked Questions

Q1: What are the primary settings for dialysis fluid flow? The W-T2008-B allows for a selectable dialysis fluid flow range between 300 and 800 mL/min to suit different clinical needs.
Q2: Does the machine include a backup power source? Yes, it is equipped with a standby battery that can supply continuous power for approximately 30 minutes in case of an outage.
Q3: Which dialyzers are compatible with this machine? The machine is highly versatile and suitable for both low flux and high flux dialyzers.
Q4: How does the ultrafiltration (UF) control system work? It utilizes a UF control system with a sealed double volume balancing chamber and offers 8 types of UF profiling for precise treatment.
Q5: What safety features are integrated into the system? The device includes an automatic self-checking function, a blood leak detector with high sensitivity (≤0.35 mL blood/min), and multiple disinfection modes.
Q6: What is the display interface size? The machine features a large 15-inch LCD touch screen for clear monitoring and easy operation by medical staff.