Hemodialysis Machine in Nephrology Dept

Still deciding? Get samples of $ !
Request Sample

Product Description

Basic Specifications

Device Type
Human Blood Processor
Attribute
Department of Nephrology
Place of Use
Hospitals, Clinics and Emergency Centers
Transport Package
Wooden Carton
Specification
142cm x 49cm x 51cm
Origin
China
HS Code
9018904000
Production Capacity
1000 units/Month

Haemodialysis Machine W-T2008-B (HD)

Certification: With CE Certificate, IEC60601

◈ 15-inch LCD touch screen
◈ Double needle dialysis treatment
◈ Balance chamber + UF pump
◈ UF control system with sealed double volume balancing chamber
◈ 8 kinds of UF profiling for clinical requirements
◈ With Na, Bicarbonate and UF profiling
◈ Standby battery (supplies power for 30 minutes)
◈ Isolated UF function
◈ Suitable for low flux and high flux dialyzer
◈ Automatic self-checking function

Technical Data

ModelW-T2008-B
Dimensions (H*W*L)142cm x 49cm x 51cm
Floor Area65*45cm²
WeightApprox. 80KG
Input Power1500W
Circuit Voltage100-240Vac
Water Inlet Pressure0.1Mpa~0.6Mpa (15P.S.I~60P.S.I)
Water Inlet Temp5ºC~30ºC
Working Env10ºC~30ºC (Rel. humidity <=70%)

Disinfection & Sanitize Protocols

1. Hot Disinfection
30 mins; ~80ºC; Flow rate 500ml/min
2. Chemical Disinfection
30 mins; 36ºC~50ºC; Flow rate 500ml/min
3. Chemical with Heat
45 mins; 36ºC~80ºC; Flow rate 50ml/min
4. Rinse
10 mins; ~37ºC; Flow rate 800ml/min

Detailed Parameters

Dialysis Fluid FlowSelectable 300-800 mL/min
Temperature RangeSelectable 34.0ºC to 40.0ºC
Conductivity Range12 to 16 mS/cm (Accuracy ±0.1 mS/cm)
Acid ConcentrationDefault 1+34; Range 125 to 150 mmol/L
Heparin Pump0ml/h to 10ml/h; Syringe: 10, 20, 30, 50ml
Ultrafiltration Rate0ml/h~4000ml/h (Accuracy ±1%)
Blood Leak DetectorSensitivity ≤0.35 mL blood/min (HCT=32)
Optional Functions:
  • On-line BPM & Kt/V
  • Bi-cart Holder
  • Bacterial Filter Device
  • Patient Management Software System

Frequently Asked Questions

Q1: What are the primary settings for dialysis fluid flow? The W-T2008-B allows for a selectable dialysis fluid flow range between 300 and 800 mL/min to suit different clinical needs.
Q2: Does the machine include a backup power source? Yes, it is equipped with a standby battery that can supply continuous power for approximately 30 minutes in case of an outage.
Q3: Which dialyzers are compatible with this machine? The machine is highly versatile and suitable for both low flux and high flux dialyzers.
Q4: How does the ultrafiltration (UF) control system work? It utilizes a UF control system with a sealed double volume balancing chamber and offers 8 types of UF profiling for precise treatment.
Q5: What safety features are integrated into the system? The device includes an automatic self-checking function, a blood leak detector with high sensitivity (≤0.35 mL blood/min), and multiple disinfection modes.
Q6: What is the display interface size? The machine features a large 15-inch LCD touch screen for clear monitoring and easy operation by medical staff.

Related Products